Select Page

EN 14509:2013 is a standard for Self-supporting double skin metal faced insulating panels. Factory made products. Specifications

EN 14509 is a harmonized EU standard which specifies the criteria for manufacturing and testing sandwich panels with metal facings. It covers the following:

structural performance, thermal insulation, fire resistance, and durability.

Compliance with EN 14509 is important for those manufacturers that are aiming to sell the products within the European Union, and other countries and beyond, as it ensures that their panels meet stringent safety and performance requirements.

The main aim of EN 14509 standard is to provide manufacturers with best industry practices (Quality and Safety included) to demonstrate the performance of thermal insulation products, such that they are fit (Quality and Safety included) for the intended use. 

BS EN 14509 specifies requirements for factory made, self-supporting, double skin metal faced 

insulating sandwich panels, which are intended for discontinuous laying in the following applications: 

  • Roofs and roof cladding 
  • External walls and wall cladding 
  • Walls (including partitions) and ceilings within the building envelope 

The insulating core materials covered by BS EN 14509 are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool. 

Testing Requirements as per EN 14509:

1. Mechanical / Structural Performance Tests

    • Bending resistance & stiffness

o 4-point bending test

o Determines maximum load, deflection, and failure mode

    • Support reaction (bearing) test
    • Shear strength of the core
    • Pull-out resistance of fasteners
    • Tensile strength perpendicular to faces (core adhesion test)

2. Thermal Performance Tests

    • Thermal conductivity (λ-value)

o Tested as per EN 12667 / EN 12939

    • Thermal resistance (R-value)
    • Thermal transmittance (U-value)
      (calculated from tested λ-values)

3. Fire Performance Tests (Mandatory for CE Marking)

    • Reaction to fire classification

o Tested as per EN 13501-1

    • Tests may include:

o Single Burning Item (SBI)

o Ignitability

o Heat release

o Smoke production

o Flaming droplets

Output: Euroclass rating (A1, A2, B, C, D, E, F)

4. Durability & Environmental Resistance

    • Hygrothermal behaviour

o Heat-cold cycling

o Freeze-thaw resistance

    • Water absorption of the core
    • Ageing resistance
    • Resistance to moisture ingress

5. Acoustic Performance (If Claimed)

    • Sound insulation (Rw)
    • Sound absorption coefficient (αw)

These tests are optional, required only if acoustic performance is declared.

6. Air & Water Tightness

    • Air permeability
    • Water tightness under pressure

7. Dimensional & Physical Checks

  • Panel thickness, width, length tolerances
  • Flatness and straightness
  • Face thickness and coating thickness

8. Surface & Corrosion Resistance

    • Coating adhesion
    • Salt spray test
    • Resistance to corrosion (depending on coating system)

9. Factory Production Control (FPC) – Ongoing Tests

    • Core density verification
    • Bond strength checks
    • Visual inspections
    • Dimensional checks
    • Batch traceability

CE Marking requirements against EN 14509:

1. Applicable Regulation

    • Construction Products Regulation (EU) No. 305/2011 (CPR)
    • EN 14509 – Self-supporting double-skin metal faced insulating panels

2. System of Assessment (AVCP)

    • System 1 → when fire performance is declared
    • System 3 → when fire performance is not declared

3. Initial Type Testing (ITT)

Conducted by authorized laboratories for the tests as written above including, for example:

    • Mechanical resistance & stability
    • Reaction to fire (if declared)
    • Thermal performance
    • Durability characteristics

4. Factory Production Control (FPC) requirements

    • Technical Construction File (TCF) documentation and implementation by manufacturer
    • Includes the entire supply chain- incoming material quality checks, in-process controls (during manufacturing and storage) , final inspection (before dispatch), identification & traceability.

5. Authorised/Approved Body Involvement

    • System 1: The Authorised/Approved Body performs

o Audit and Initial inspection of factory as per FPC requirements

o Annual Surveillance of FPC requirements

o Issues Certificate, including as required CE Marking certificate

    • System 3: Notified Body limited to ITT only

6. Declaration of Performance (DoP)

    • Mandatory document.
    • As per EN 14509 Annex ZA

7. CE Marking & Labelling

    • CE Marking is affixed to product/packaging/documentation
    • Includes as per the EU Directive/Regulation:

o DoP reference

o Manufacturer details/Address

o Declared performances

o EN 14509 and other standards’ reference

Annex ZA — Explained Simply

What is Annex ZA

The requirements mainly within EN 14509 and how it relates to the Construction Products Regulation (EU) No. 305/2011 (CPR). It gives requirements about what to declare, how to assess, and who does what.

What it specifies:

  1. Essential Characteristics
    The performance items those that are to be declared (e.g., mechanical resistance, thermal performance, reaction to fire, durability).
  2. AVCP System
    Which system applies (1 or 3) based on whether fire performance is declared.
  3. Responsibilities

o Manufacturer: FPC, DoP, CE marking

o Authorised / Approved Body: ITT (System 3 or System 1); ITT + factory/FPC certification & annual surveillance (System 1)

  1. CE Marking Information
    Exactly what information must appear with the CE mark.

How to use Annex ZA (practical)

  • Pick the essential characteristics to be declared
  • Apply the correct AVCP system
  • Complete the documentation and ITT + FPC accordingly
  • Draft the DoP aligned to Annex ZA
  • Place the CE Marking with required details

EN 14509 testing ensures that manufactured sandwich panels meet critical quality and safety benchmarks, providing confidence to clients and stakeholders. Hence Panels tested to this standard offer:

  • Structural Safety: Assurance that Certified panels can withstand mechanical stresses and environmental loads without failure according to EN 14509.
  • Energy Efficiency: Assurance that Thermal performance testing guarantees that buildings equipped with these panels meet modern energy-saving standards.
  • Fire Safety: Ensuring compliance (System 3) with fire regulations minimizes risks to life and property according to EN 14509.
  • Longevity: Panels are proven to withstand aging factors, reducing maintenance costs over time.

Conclusion:

Adherence to EN 14509 and CE Marking certification is greater than a plain regulatory requirement; it is the manufacturer’s commitment to quality, safety, and sustainability.